Features: Suitable for handling surge voltages of up to 2 kV according to the directives of Germany's telecom administration Suitable for handling the surge current of the 10/700 s pulse to ITU-T and IEC 61000-4-5 Matched to line conditions with or without superimposed ringing voltage Good solder...
CT1812S60AG2: Features: Suitable for handling surge voltages of up to 2 kV according to the directives of Germany's telecom administration Suitable for handling the surge current of the 10/700 s pulse to ITU-T a...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: Suitable for handling surge voltages of up to 2 kV according to the directives of German...
Features: Suitable for handling surge voltages of up to 2 kV according to the directives of German...
Features: Suitable for handling surge voltages of up to 2 kV according to the directives of German...
Type SIOVO |
rdering code |
VRMS V |
VDC V |
i (10 ) 10/700 ~s A1) |
imax 8/20 s A |
Wmax (2 ms) J |
Pmax W |
CT1812S60AG2 |
B72580T0600S172 |
60 |
85 100 125 150 170 |
45 45 45 45 45 |
400 400 250 250 250 |
2,2 2,5 2,8 3,2 3,5 |
0,015 0,015 0,015 0,015 0,015 |