Features: Energy Data Linearity: 0.1% of Reading over 1000:1 Dynamic RangeOn-Chip Functions: Energy, I ∗ V,IRMS and VRMS, Energy to Pulse-Rate ConversionComplies with IEC 687/1036, JISPower Consumption <12 mWInterface Optimized for Shunt SensorPhase CompensationGround-Referenced Signals w...
CS5460: Features: Energy Data Linearity: 0.1% of Reading over 1000:1 Dynamic RangeOn-Chip Functions: Energy, I ∗ V,IRMS and VRMS, Energy to Pulse-Rate ConversionComplies with IEC 687/1036, JISPower Co...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbol |
Min |
Typ |
Max |
Unit | |
DC Power Supplies |
(Notes 9 and 10) |
|||||
Positive Digital |
VD+ |
-0.3 |
- |
+6.0 |
V | |
Positive Analog |
VA+ |
-0.3 |
- |
+6.0 |
V | |
Negative Analog |
VA- |
+0.3 |
- |
-6.0 |
V | |
Input Current, Any Pin Except Supplies (Note 11 and 12) |
IIN |
- |
- |
±10 |
mA | |
Output Current |
IOUT |
- |
- |
±25 |
mA | |
Power Dissipation (Note 13) |
PDN |
- |
- |
500 |
mW | |
Analog Input Voltage All Analog Pins |
VINA |
- 0.3 |
- |
(VA+) + 0.3 |
V | |
Digital Input Voltage All Digital Pins |
VIND |
- 0.3 |
- |
(VD+) + 0.3 |
V | |
Ambient Operating Temperature |
TA |
-40 |
- |
85 |
°C | |
Storage Temperature |
Tstg |
-65 |
- |
150 |
°C |
The CS5460 is a highly integrated ∆ Analog-to-Digital Converter (ADC) which combines two ∆ ADCs, high speed power calculation functions, and a serial interface on a single chip. It is designed to accurately measure and calculate: Energy, Instantaneous Power, IRMS, and VRMS for single phase 2 or 3-wire power meter applica-tions. The CS5460 interfaces to a low cost shunt or transformer to measure current, and resistive divider or transformer to measure voltage. The CS5460 features a bi-directional serial interface for communication with a micro-controller and a fixed-width programmable fre-quency output that is proportional to energy. The product is initialized and fully functional upon power-up, and in-cludes facilities for system-level calibration under control
of the user program.