Features: • Metal Case for Maximum Heat Dissipation.• Surge Overload Ratings to 400 Amperes.• These bridges are on the U/L Recognized Products List for currents of 50 amperes.SpecificationsRatings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60...
CM5007: Features: • Metal Case for Maximum Heat Dissipation.• Surge Overload Ratings to 400 Amperes.• These bridges are on the U/L Recognized Products List for currents of 50 amperes.Speci...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, Resistive or inductive load. For capacitive load, derate current by 20%
CM5000 | CM5001 | CM5002 | CM5004 | CM5006 | CM5008 | CM5010 | UNITS | |
Maximum Recurrent Peak Reverse Voltage | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | V |
Maximum RMS Bridge input Voltage | 35 | 70 | 140 | 280 | 420 | 560 | 700 | V |
Maximum DC Blocking Voltage | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | V |
Maximum Average Forward Current TA=55°C |
50.0 |
A | ||||||
Non-repetitive Peak Forward Surge Current , rated load |
400 |
A | ||||||
Maximum Forward Voltage per Bridge Element Specified Current at 25A |
1.2 |
V | ||||||
Maximum Reverse Current at Rated DC Blocking Voltage per element |
10.0 |
A | ||||||
I2t Rating for fusing ( t < 8.35 ms) |
664 |
A2S | ||||||
Typical Thermal resistance ( Fig 3) RJC |
2.5 |
°C/W | ||||||
Operating Temperature Range TJ |
-55 to +150 |
°C | ||||||
Storage Temperature Range TA |
-55 to +150 |
°C |