Features: ·The plastic package carries Underwriters Laboratory Flammability Classification 94V-0·Construction utilizes void-free molded plastic technique·Low reverse leakage·Low forward voltage drop·High current capability·High reliability·High surge current capabilitySpecifications ...
BY127: Features: ·The plastic package carries Underwriters Laboratory Flammability Classification 94V-0·Construction utilizes void-free molded plastic technique·Low reverse leakage·Low forward voltage drop...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbols |
BY127 |
BY133 |
EM513 |
EM516 |
UNITS |
|
Maximum Recurrent Peak Reverse Voltage | VRRM |
50 |
100 |
150 |
200 |
Volts |
Maximum RMS Voltage | VRMS |
35 |
70 |
105 |
140 |
Volts |
Maximum DC Blocking Voltage | VDC |
50 |
100 |
150 |
200 |
Volts |
Maximum average forward rectified current 0.375" (9.5mm) lead length at TA=75 |
I(AV) |
1.0 |
Amp |
|||
Peak Forward Surge Current, 8.3ms single half sine-wave superimposed on rated load(JEDEC method) |
IFSM |
30.0 |
Amps |
|||
Maximum forward voltage at 1.0A DC and 25 | VF |
1.1 |
Volts |
|||
Maximum DC Reverse Current at Ta=25 DC Blocking Voltage per element Ta=100 |
IR |
5.0 200.0 |
A |
|||
Typical Junction capacitance (Note 1) | CJ |
15.0 |
pF |
|||
Maximum Reverse Recovery Time(Note 2) | RJA RJL |
50.0 25.0 |
/W |
|||
Operating and storage temperature range | TJ, TSTG |