Features: · Logic Level Input· Input Protection (ESD)· Thermal Shutdown· Overload protection· Short circuit protection· Overvoltage protection· Current limitation· Maximum current adjustable with external resistor· Current sense· Status feedback with external input resistor· Analog driving possibl...
BTS941: Features: · Logic Level Input· Input Protection (ESD)· Thermal Shutdown· Overload protection· Short circuit protection· Overvoltage protection· Current limitation· Maximum current adjustable with ex...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol |
Value |
Unit |
Drain source voltage | VDS |
60 |
V |
Drain source voltage for short circuit protection RCC = 0 without RCC |
VDS(SC) |
15 50 | |
Continuous input current 1) -0.2V VIN 10V VIN < -0.2V or VIN > 10V |
IIN |
no limit | IIN | 2 |
mA |
Operating temperature | Tj |
- 40 ... +150 |
°C |
Storage temperature | Tstg |
- 55 ... +150 | |
Power dissipation TC = 25 °C |
Ptot |
149 |
W |
Unclamped single pulse inductive energy I D(ISO) = 12 A |
EAS |
4000 |
mJ |
Electrostatic discharge voltage (Human Body Model) according to MIL STD 883D, method 3015.7 and EOS/ESD assn. standard S5.1 - 1993 |
VESD |
3000 |
V |
Load dump protection VLoadDump2) = VA + VS VIN=low or high; VA=13.5 V td = 400 ms, RI = 2 , ID=0,5*12A td = 400 ms, RI = 2 , ID= 12A |
VLD |
110 84 | |
DIN humidity category, DIN 40 040 |
E |
||
IEC climatic category; DIN IEC 68-1 |
40/150/56 |