Specifications Symbol Parameter Value Unit I T(RMS) RMS on-state current(full sine wave) RD91 Tc = 80°C 40 A TOP3 TOP3 Ins. Tc = 70°C ITSM Non repetitive surge peak on-statecurrent (full cycle, Tj initial = 25°C F = 60 Hz t = 16.7 ms ...
BTA40: Specifications Symbol Parameter Value Unit I T(RMS) RMS on-state current(full sine wave) RD91 Tc = 80°C 40 A TOP3 TOP3 Ins. Tc = 70°C ITSM No...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol |
Parameter |
Value |
Unit | ||
I T(RMS) |
RMS on-state current (full sine wave) |
RD91 |
Tc = 80°C |
40 |
A |
TOP3 | |||||
TOP3 Ins. |
Tc = 70°C | ||||
ITSM |
Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C |
F = 60 Hz |
t = 16.7 ms |
420 |
A |
F = 50 Hz |
t = 20 ms |
400 | |||
It |
It Value for fusing |
tp = 10 ms |
1120 |
A s | |
dI/dt |
Critical rate of rise of on-state current IG = 2 x IGT , tr 100 ns |
F = 120 Hz |
Tj = 125°C |
50 |
A/ms |
VDSM/VRSM |
Non repetitive surge peak off-state voltage |
tp = 10 ms |
Tj = 25°C |
VDRM/VRRM + 100 |
v |
I GM |
Peak gate current |
tp = 20s |
Tj = 125°C |
8 |
A |
P G(AV) |
Average gate power dissipation |
Tj = 125°C |
1 |
W | |
T stg T j |
Storage junction temperature range Operating junction temperature range |
- 40 to + 150 - 40 to + 125 |
°C |
Available in high power packages, the BTA/ BTB40-41 series is suitable for general purpose AC power switching.BTA40 can be used as an ON/ OFF function in applications such as static relays, heating regulation, water heaters, induction motor starting circuits, welding equipment... or for phase control operation in high power motor speed controllers, soft start circuits...
Thanks to their clip assembly technique,BTA40 provide a superior performance in surge current handling capabilities.
By using an internal ceramic pad, the BTA series BTA40 provides voltage insulated tab (rated at 2500 V RMS) complying with UL standards (File ref.: E81734).