ApplicationThese products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and ...
BTA225B: ApplicationThese products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.
SYMBOL |
PARAMETER | CONDITIONS |
MIN. |
MAX. |
UNIT | ||
VDRM | Repetitive peak off-state voltages |
- |
-500 5001 |
-600 |
-800 |
V | |
IT(RMS) | RMS on-state current | full sine wave; Tmb 91 |
- |
25 |
A | ||
ITSM | Non-repetitive peak on-state current |
full sine wave; Tj =25 prior to surge; |
|||||
t= 20 ms |
- |
190 |
A | ||||
t = 16.7 ms |
- |
209 |
A | ||||
I2t | I2t for fusing | t = 10 ms |
- |
180 |
A2S | ||
dlT/dt | Repetitive rate of rise of on-state current after triggering |
ITM = 30 A; IG =0.2A; dlG/dt = 0.2 A/S |
100 |
A/S | |||
IGM | PPeak gate current |
- |
2 |
A | |||
VGM | Peak gate voltage |
- |
5 |
V | |||
PGM | Peak gate power |
- |
5 |
W | |||
PG(AV) | Average gate power | over any 20 msperiod |
- |
0.5 |
W | ||
Tstg | Storage temperature |
-40 |
150 |
||||
Tj | Operating Junction temperature |
- |
125 |
Glass passivated high commu tation triacs in a plasti cenvelop esuitable for surface mounting,i ntended for use in circuits where high static anddynamic dV/dt and highdI/dt can occur.BTA225B will commu tatethe full rate rms current at the maximum rated unction temperature,with out the aid of asnubber.