Features: · Logic Level Input· Input protection (ESD)· Thermal shutdown (with restart)· Overload protection· Short circuit protection· Overvoltage protection· Current limitationApplication· All kinds of resistive, inductive and capacitive loads in switching applications· mC compatible power switch...
BSP 75A: Features: · Logic Level Input· Input protection (ESD)· Thermal shutdown (with restart)· Overload protection· Short circuit protection· Overvoltage protection· Current limitationApplication· All kind...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbol |
Values |
Unit |
Continuous drain source voltage (overvoltage protection see page 4) |
VDS |
55 |
V |
Drain source voltage for short circuit protection |
VDS |
32 |
V |
Load dump protectionVLoadDump=UP+US; UP=13.5 V RI 1)=2 W; td=400ms; IN=low or high (8V) RL=50 W RI=2 W; td=400ms; IN=high (8V) RL=22 W |
VLoadDump 2) |
80 47 |
V |
Continuous input voltage |
VIN |
-0.2 ... +10 |
V |
Peak input voltage |
VIN |
-0.2 ... +20 |
V |
Operating temperature range Storage temperature range |
Tj Tstg |
-40 ...+150 -55 ...+150 |
°C |
Power dissipation (DC) |
Ptot |
1.8 |
W |
Unclamped single pulse inductive energy ID(ISO) = 0.7 A |
EAS |
550 |
mJ |
Electrostatic discharge voltage (Human Body Model) according to MIL STD 883D, method 3015.7 and EOS/ESD assn. standard S5.1 - 1993 |
VESD |
4000 |
V |
DIN humidity category, DIN 40 040 |
E |
||
IEC climatic category, DIN IEC 68-1 |
40/150/56 |