Features: • Low power loss, high efficiency• Low profile surface mount package• Built-in strain relief• For use in low voltage high frequency inverters, free wheeling, and polarity protection applications• Guardring for overvoltage protection• Plastic package ha...
B230LA: Features: • Low power loss, high efficiency• Low profile surface mount package• Built-in strain relief• For use in low voltage high frequency inverters, free wheeling, and po...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol | B230LA | B240A | Unit |
Device marking code | B23 | B24 | V | |
Maximum repetitive peak reverse voltage | VRRM | 30 | 40 | V |
Maximum RMS voltage | VRMS | 21 | 28 | V |
Maximum DC blocking voltage | VDC | 30 | 40 | V |
Maximum average forward rectified current at TL (See Fig. 1) |
IF(AV) | 2.0 | A | |
Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) |
IFSM | 50 | A | |
Typical thermal resistance (2) | RJA RJL |
110 28 |
°C/W | |
Voltage rate of change (rated VR) | dv/dt | 10,000 | V/s | |
Operating junction temperature range | TJ | -65 to + 150 | °C | |
Storage temperature range | TSTG | -65 to + 150 | °C |