Operational Type : | Complementary Output Hall Effect Latch | Operating Supply Voltage : | 20 V | ||
Current Rating : | 400 mA | Package / Case : | SIP-4L | ||
Output Fall Time : | 1.5 uS | Operating Point Min/Max : | 5 G to 70 G |
Characteristics |
Symbol |
Values |
Unit | |
Supply voltage |
VCC |
20 |
V | |
Reverse VCC Polarity Voltage |
VRCC |
-20 |
V | |
Magnetic flux density |
B |
Unlimited | ||
Output "on" current | Continuous |
Ic |
0.4 |
A |
Hold |
0.5 | |||
Peak (Start Up) |
0.7 | |||
Operating temperature range |
Ta |
-20~+85 |
°C | |
Storage temperature range |
Ts |
-65~+150 |
°C | |
Package Power Dissipation |
PD |
550 |
mW | |
Maximum Junction Temp |
Tj |
150 |
°C |
ATS276/277 are integrated Hall sensors with output drivers, mainly designed for electronic commutation of brush-less DC Fan. This IC internally includes the regulator, protecting diode, Hall plate, amplifier, comparator, and a pair of complementary open-collector outputs (DO, DOB).
While the magnetic flux density (B) is larger than operate point (Bop), DO will turn on (low), and meanwhile DOB will turn off (high). Each output is latched until B is lower than release point (Brp), and then DO,DOB transfer each state. For DC fan application, sometimes ATS276 need to test power reverse connection condition. Internal diode only protects chip-side but not for coil-side. If necessary, add one external diode to block the reverse current from coil-side.