Features: * ARX4435N transceiver meets Macair H009 data bus specifications* Transmitter can be used to drive clock signal line* Operates with ±15 Volts to ±12 Volts power supplies* Low power direct replacement for CT1641 and CT1816 devices* Voltage source output for higher bus drive power * Plug-i...
ARX4435N: Features: * ARX4435N transceiver meets Macair H009 data bus specifications* Transmitter can be used to drive clock signal line* Operates with ±15 Volts to ±12 Volts power supplies* Low power direct ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Operating Case Temperature | -55°C to +125°C | |
Storage Case Temperature | -65°C to +150 °C | |
Power Supply Voltages | ±15 V P.S. to ±18V MAX | +5 V P.S. to +7V MAX |
Logic Input Voltage | -0.3 V to +5.5 V | |
Receiver Differential Input | ±40 V | |
Receiver Input Voltage (Common Mode) | ±10V | |
Driver Peak Output Current | 150 mA | |
Total Package Power Dissipation over the Full Operating Case Temperature Range |
3.0 Watts | |
Maximum junction to case temperature rise for the hottest device (100 % duty cycle) |
15°C | |
Junction-Case, Thermal Resistance for hottest device | 5°C/W |
The Aeroflex Laboratories Incorporated model ARX4435N and ARX4435NFP are new generation monolithic transceivers which provides compliance with Macair H009 data bus requirements.
The ARX4435N and ARX4435NFP perform the front-end analog function of inputting and outputting data through a transformer to a H009 data bus.
Design of these transceivers reflects particular attention to active filter performance.ARX4435N results in low bit and word error rate withsuperior waveform purity and minimal zero crossover distortion.The ARX4435N series active filter design has additional high frequency roll-off to provide the required low harmonic distortion waveform without increasing the delay characteristics significantly.
Efficient transmitter ARX4435N electrical and thermal design results in low internal power dissipation and temperature rise at high and low duty cycle.