Features: Total Dose > 100KRad (Si), 2:1margin SEE hard to LET = 83 Mev.cm2 /mg Designed to MIL-PRF-38534 for Class K Derated per MIL-STD-975 & MIL-STD-1547 Output Power Range 3 to 30 Watts 19 to 50 Volt Input Range Input Undervoltage Lockout High Electrical Efficiency > 80% Full Perfor...
ART2815EM: Features: Total Dose > 100KRad (Si), 2:1margin SEE hard to LET = 83 Mev.cm2 /mg Designed to MIL-PRF-38534 for Class K Derated per MIL-STD-975 & MIL-STD-1547 Output Power Range 3 to 30 Watts ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The ART ART2815EM Series of three output DC/DC converters are designed specifically for use in the hostile radiation environments characteristic of space and weapon systems.
The extremely high level of radiation tolerance inherent in the ART ART2815EM design is the culmination of extensive research, thorough analysis of ART2815EM and testing and of careful component specification. Many of the best circuit design features characterizing the Advanced Analog standard product line were adapted for incorporation into the ART topology. Capable of uniformly high performance over long term exposures in radiation intense environments, ART2815EM sets the standard for distributed power systems demanding high performance and reliability.
The ART ART2815EM converters are hermetically sealed in a rugged, low profile package utilizing copper core pins to minimize resistive DC losses. Long-term hermeticity of ART2815EM is assured through use of parallel seam welded lid attachment along with Advanced Analog's rugged ceramic pin-to-package seal. Axial orentation of the leads facilitates preferred bulkhead mounting to the principal heat-dissipating surface.
Manufactured ART2815EM in a facility fully qualified to MIL-PRF- 38534, these converters are fabricated utilizing DSSC qualified processes, and are fully compliant to Class H while being fully processed to the requirements of Class K. Complete PI & CI testing has been completed including Group C life test. Variations in electrical, mechanical and screening specifications can be accommodated. Contact Advanced Analog for special requirements.