SpecificationsVRRM4500[V]IF(AV)sine wave 50 Hz Th=55°C790[A]IF(AV)sine wave 50 Hz Th=85°C700[A]IF(AV)sine wave 50 Hz Th=70°C865[A]IFSMsine wave 10 ms Vr<10V15[A]VDClink2800[V]VFMTj max IF = 10 kA4.65[V]IF2500[A]VF(TO)Tj max1.9[V]rFTj max1.1[mW]QrrTj max2500[µC]IrrTj max1400[A]IFTj max2100...
ARF671: SpecificationsVRRM4500[V]IF(AV)sine wave 50 Hz Th=55°C790[A]IF(AV)sine wave 50 Hz Th=85°C700[A]IF(AV)sine wave 50 Hz Th=70°C865[A]IFSMsine wave 10 ms Vr<10V15[A]VDClink2800[V]VFMTj max IF = 10 kA...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol | Characteristic | Conditions | Tj [°C] |
Value | Unit |
BLOCKING | |||||
V RRM | Repetitive peak reverse voltage |
125 | 4500 | V | |
V RSM | Non-repetitive peak reverse voltage | 125 | 4600 | V | |
I RRM | Repetitive peak reverse current | V=VRRM | 125 | 80 | MA |
V DC LINK | Permanent DC voltage | 125 | 2800 | v | |
CONDUCTING | |||||
I F (AV) | Mean forward current | 180° sin ,50 Hz, Th=55°C, double side cooled | 790 | A | |
I F (AV) | Mean forward current | 180° sin ,50 Hz, Tc=55°C, double side cooled | 820 | A | |
I FSM | Surge forward current | Sine wave, 10 ms without reverse voltage up to 50% VRSM |
125 | 15 | KA |
I² t | I² t | 1125 x 1E3 | A²s | ||
V FM | Forward voltage | Forward current =2500 A | 125 | 4.65 | V |
V F(TO) | Threshold voltage | 125 | 1.90 | V | |
r F | Forward slope resistance | 125 | 1.100 | mohm | |
SWITCHING | |||||
Q rr | Reverse recovery charge | I F = 1000 A di/dt= 250 A/µs VR = 100 V |
125 | 1000 | µC |
I rr | Peak reverse recovery current | 125 | 525 | A | |
t rr | Reverse recovery time | I F = 2100 A di/dt= 1000 A/µs VR = 1800 V |
125 | µs | |
Q rr | Reverse recovery charge | 2500 | µC | ||
I rr | Peak reverse recovery current | 1400 | a | ||
s | Softness (s-factor), min | ||||
E OFF | Turn off energy dissipation | j | |||
V FR | Peak forward recovery | di/dt = 400 A/µs | 125 | v | |
MOUNTING | |||||
R th(j-h) | Thermal impedance, DC | Junction to heatsink, double side cooled | 21 | °C/kW | |
R th(c-h) | Thermal impedance | Case to heatsink, double side cooled | 6 | °C/kW | |
T j | Operating junction temperature | -30 / 125 | °C | ||
F | Mounting force | 22.0/24.5 | kN | ||
Mass | 300 | g |