Features: • Ultrafast Recovery Times• Soft Recovery Characteristics• Popular TO-247 Package• Low Forward Voltage• High Blocking Voltage• Low Leakage CurrentApplication• Anti-Parallel Diode -Switchmode Power Supply -Inverters• Free Wheeling Diode -Mot...
APT60D40B: Features: • Ultrafast Recovery Times• Soft Recovery Characteristics• Popular TO-247 Package• Low Forward Voltage• High Blocking Voltage• Low Leakage CurrentApplic...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Specifications Symbol Parameter APT6010 UNIT VDSS Drain-Source Voltage 600 Volts ...
Symbol | Parameter |
APT60D40B |
UNIT |
VDSS | Drain-Source Voltage |
600 |
Volts |
ID | Continuous Drain Current @ TC = 25 |
15 |
Amps |
IDM | Pulsed Drain Current |
60 | |
VGS | Gate-Source Voltage |
±30 |
Volts |
VGSM | Gate-Source Voltage Transient |
±40 | |
PD | Total Power Dissipation @ TC = 25 |
250 |
Watts |
Linear Derating Factor |
2 |
W/ | |
TJ,TSTG | Operating and StorageTemperature Range |
-55 to 150 |
|
TL | Lead Temperature: 0.063" from Case for 10 Sec. |
300 | |
IAR | Avalanche Current(Repetitive and Non-epetitive) |
15 |
Amps |
EAR | Repetitive Avalanche Energy |
30 |
mJ |
EAS | Single Pulse Avalanche Energy |
960 |
Symbol | Characteristic / Test Conditions | APT60D20LCT |
UNIT |
VR | Maximum D.C. Reverse Voltage |
400 |
Volts |
VRRM | Maximum Peak Repetitive Reverse Voltage | ||
VRWM | Maximum Working Peak Reverse Voltage | ||
IF(AV) | Maximum Average Forward Current(TC =70, Duty Cycle =0.5) |
60 |
Amps |
IF(RMS) | RMS Forward Current |
100 | |
IFSM | Non-Repetitive Forward Surge Current (TJ = 45, 8.3ms) |
600 | |
TJ,TSTG | Operating and StorageTemperature Range |
-55 to 150 | |
TL | Lead Temperature: 0.063" from Case for 10 Sec. |
300 |