Features: ` Meets or Exceeds Standards TIA/EIA-422-B and ITU Recommendation V.11` Operates From a Single 3.3-V Power Supply` ESD Protection for RS422 Bus Pins ±15-kV Human-Body Model (HBM) ±8-kV IEC61000-4-2, Contact Discharge ±15-kV IEC61000-4-2, Air-Gap Discharge` Switching Rates up to 32 MHz` P...
AM26LV31E: Features: ` Meets or Exceeds Standards TIA/EIA-422-B and ITU Recommendation V.11` Operates From a Single 3.3-V Power Supply` ESD Protection for RS422 Bus Pins ±15-kV Human-Body Model (HBM) ±8-kV IEC...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
MIN |
MAX |
UNIT | ||
VCC Supply voltage range(2) |
0.5 |
6 |
V | |
VI Input voltage range |
0.5 |
6 |
V | |
VO Output voltage range |
0.5 |
6 |
V | |
IIK Input clamp current range | VI < 0 |
20 |
mA | |
IOK Output clamp current range | VO < 0 |
20 |
mA | |
lO Maximum output current |
±150 |
mA | ||
Continuous current through VCC or GND |
±200 |
mA | ||
TJ Operating virtual junction temperature |
150 |
|||
JA Package thermal impedance(3) (4) | D package |
73 |
/W | |
NS package |
64 | |||
PW package |
108 | |||
RGY package |
39 | |||
TA Operating free-air temperature range |
40 |
85 |
||
Tstg Storage temperature range |
65 |
150 |
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values except differential input voltage are with respect to the network GND.
(3) Maximum power dissipation is a function of TJ(max), JA, and TA. The maximum allowable power dissipation at any allowable ambient temperature is PD = (TJ(max) TA)/JA. Selecting the maximum of 150 can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
The AM26LV31E is a quadruple differential line driver with 3-state outputs. This driver has ±15-kV ESD (HBM and IEC61000-4-2, Air-Gap Discharge) and ±8-kV ESD (IEC61000-4-2, Contact Discharge) protection. This device is designed to meet TIA/EIA-422-B and ITU Recommendation V.11 drivers with reduced supply voltage.
The device is optimized for balanced-bus transmission at switching rates up to 32 MHz. The outputs have high current capability for driving balanced lines, such as twisted-pair transmission lines, and provide a high impedance in the power-off condition.
The AM26LV31EI is characterized for operation from 40 to 85.