Features: • 600W continuous power at 100°C baseplate temperature• 108W/in3 (6.6W/cm3)• High efficiency 91.8% typical• Low output ripple and noise• Positive and Negative Enable function• Excellent transient response• OVP, OCP, V Adj control with ALPTM anal...
AIF12W300: Features: • 600W continuous power at 100°C baseplate temperature• 108W/in3 (6.6W/cm3)• High efficiency 91.8% typical• Low output ripple and noise• Positive and Negativ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol | Min | Typ | Max | Unit |
Input Voltage: Continuous: Transient (100ms) |
VI VI, trans |
250 | - | 420 500 |
Vdc Vdc |
Operating Baseplate Temperature | Tc | -20 | - | 100 | °C |
Start up Baseplate Temperature | - | -40 | - | 100 | °C |
Storage Temperature | TSTG | -55 | - | 125 | °C |
Operating Humidity | - | 15 | - | 95 | % |
I/O Isolation | - | 2700 | - | - | Vdc |
The single output AIF is an isolated, single output DC to DC converter module, providing up to 600W output with a maximum baseplate operating temperature of 100°C with no derating. The AIF features full safety isolated low voltage secondary side control and Astec Linear Programming (ALP™) or through I2C bus for convenient adjustment of the module's parameters.