Features: · Temperature protection provided by directly detecting the junction temperature of the IGBTs· Low power loss and soft switching· High performance and high reliability IGBT with overheating protection· Higher reliability because of a big decrease in number of parts in built-in control ci...
7MBP100RTB060: Features: · Temperature protection provided by directly detecting the junction temperature of the IGBTs· Low power loss and soft switching· High performance and high reliability IGBT with overheatin...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: · Temperature protection provided by directly detecting the junction temperature of the ...
Features: · Temperature protection provided by directly detecting the junction temperature of the ...
Features: · Temperature protection provided by directly detecting the junction temperature of the ...
· Temperature protection provided by directly detecting the junction temperature of the IGBTs
· Low power loss and soft switching
· High performance and high reliability IGBT with overheating protection
· Higher reliability because of a big decrease in number of parts in built-in control circuit
Item |
Symbol |
Rating |
Unit | |||
Min. |
Max. | |||||
Bus voltage |
DC |
VDC |
0 |
450 |
V | |
Surge |
VDC(surge) |
0 |
500 |
V | ||
Short operating |
VSC |
200 |
400 |
V | ||
Collector-Emitter voltage *1 |
VCES *1 |
0 |
600 |
V | ||
Inverter | Collector current |
DC |
IC |
- |
100 |
A |
1ms |
ICP |
- |
200 |
A | ||
Duty=72.3% |
-IC *2 |
- |
100 |
A | ||
Collector power dissipation |
One transistor |
PC *3 |
- |
347 |
W | |
Brake | Collector current |
DC |
IC |
- |
50 |
A |
1ms |
ICP |
- |
100 |
A | ||
Forward current diode |
IF |
- |
50 |
A | ||
Collector power dissipation |
One transistor |
PC *3 |
- |
198 |
W | |
Supply voltage of Pre-Driver |
VCC *4 |
-0.5 |
20 |
V | ||
Input signal voltage |
Vin *5 |
-0.5 |
Vcc+0.5 |
V | ||
Input signal current |
Iin |
- |
3 |
mA | ||
Alarm signal voltage |
VALM *6 |
-0.5 |
Vcc |
V | ||
Alarm signal current |
IALM *7 |
- |
20 |
mA | ||
Junction temperature |
Tj |
- |
150 |
|||
Operating case temperature |
Top |
-20 |
100 |
|||
Storage temperature |
Tstg |
-40 |
125 |
|||
Isolating voltage (Case-Terminal) |
Vis *8 |
- |
AC2.5 |
kV | ||
Screw torque |
Mounting (M5) |
- |
3.5*9 |
N`m | ||
Mounting (M5) |
- |
3.5*9 |
N`m |
Note
*1 : Vces shall be applied to the input voltage between terminal P and U or V or W or DB, N and U or V or W or DB.
*2 : 125°C/FWD Rth(j-c)/(Ic x VF MAX)=125/0.665/(100 x 2.6)x100=72.3%
*3 : Pc=125°C/IGBT Rth(j-c)=125/0.36=347W [Inverter]
Pc=125°C/IGBT Rth(j-c)=125/0.63=198W [Break]
*4 : Vcc shall be applied to the input voltage between terminal No. 3 and 1, 6 and 4, 9 and 7, 11 and 10.
*5 : Vin shall be applied to the input voltage between terminal No. 2 and 1, 5 and 4, 8 and 7, 12,13,14,15 and 10.
*6 : VALM shall be spplied to the voltage between terminal No. 16 and 10.
*7 : IALM shall be applied to the input current to terminal No. 16.
*8 : 50Hz/60Hz sine wave 1 minute.
*9 : Recommendable Value : 2.5 to 3.0 N`m