Features: •256k x 32-bit EEPROM MCM•RAD-PAK® radiation-hardened against natural •space radiation•Total dose hardness:- >100 krad (Si)- Dependent upon orbit•Excellent Single event effects- SELTH> 120 MeV/mg/cm2- SEU > 90 MeV/mg/cm2 read mode- SEU = 18 MeV/...
79C0832: Features: •256k x 32-bit EEPROM MCM•RAD-PAK® radiation-hardened against natural •space radiation•Total dose hardness:- >100 krad (Si)- Dependent upon orbit•Excel...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PARAMETER | SYMBOL | MIN | TYP | MAX | UNIT |
Supply Voltage | VCC | -0.6 | 7.0 | V | |
Input Voltage | VIN | -0.51 | 7.0 | V | |
Package Weight | RP | 45 | Grams | ||
RT | 38 | ||||
XP | TBD | ||||
Thermal Impedance | Fjc | 3 | °C/W | ||
Operating Temperature Range | TOPR | -55 | 125 | °C | |
Storage Temperature Range | TSTG | -65 | 150 | °C |
Maxwell Technologies' 79C0832 multi-chip module (MCM) memory features a greater than 100 krad (Si) total dose toler-ance, dependent upon orbit. Using Maxwell Technologies' pat-ented radiation-hardened RAD-PAK® MCM packaging technology, the 79C0832 is the first radiation-hardened 8 megabit MCM EEPROM for space application. The 79C0832 uses eight 1 Megabit high speed CMOS die to yield an 8 megabit product. The 79C0832 is capable of in-system electri-cal byte and page programmability. It has a 128 x 8 byte page programming function to make its erase and write operations faster. It also features Data</a> Polling and a Ready/Busy</a> signal to indicate the completion of erase and programming operations.In the 79C0832, hardware data protection is provided with the RES</a> pin, in addition to noise protection on the WE</a> signal and write inhibit on power on and off. Software data protection is implemented using the JEDEC optional standard algorithm.
Maxwell Technologies' patented RAD-PAK® packaging technol-ogy incorporates radiation shielding in the microcircuit pack-age. It eliminates the need for box shielding while providing the required radiation shielding for a lifetime in orbit or space mission. In a GEO orbit, RAD-PAK of the 79C0832 provides greater than 100 krad (Si) radiation dose tolerance. This product is available with screening up to Maxwell Technologies self-defined Class K.