SYMBOL | PARAMETER | RATING | UNIT | |
VCC | Supply voltage | 0.5 to +7.0 | V | |
VIN | Input voltage | 0.5 to +7.0 | V | |
IIN | Input current | 30 to +5 | mA | |
VOUT | Voltage applied to output in high output state | 0.5 to VCC | V | |
IOUT | Current applied to output in low output state | 74F646A, 74F648A | 72 | mA |
74F646, 74F648 | 128 | mA | ||
Tamb | Operating free air temperature range | 0 to +70 | °C | |
Tstg | Storage temperature range | 65 to +150 | °C |
The 74F648 transceivers/registers consist of bus transceiver circuits with 3state outputs, Dtype flipflops, and control circuitry arranged for multiplexed transmission of data directly from the input bus or the internal registers. Data on the A or B bus will be clocked into the registers as the appropriate clock pin goes high. Output enable (OE) and DIR pins of the 74F648 are provided to control the transceiver function. In the transceiver mode, data present at the high impedance port may be stored in either the A or B register or both.
The select (SAB, SBA) pins of the 74F648 determine whether data is stored or transferred through the device in realtime. The DIR determines which bus will receive data when the OE is active low. In the isolation mode (OE = high), data from bus A may be stored in the B register and/or data from bus B may be stored in the A register. When an output function is disabled, the input function is still enabled and may be used to store and transmit data. Only one of the two buses, A or B may be driven at a time.