DescriptionThe 700-HA is designed as general purpose relay which has pin-style terminals and is availavle in 2-pole (DPDT) or 3-pole (3PDT). It features a standard ON/OFF flag indicator, and can be ordered with an optional push-to-test operator, a LED and bifurcated or gold bifurcated contacts. Co...
700-HA: DescriptionThe 700-HA is designed as general purpose relay which has pin-style terminals and is availavle in 2-pole (DPDT) or 3-pole (3PDT). It features a standard ON/OFF flag indicator, and can be ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The 700-HA is designed as general purpose relay which has pin-style terminals and is availavle in 2-pole (DPDT) or 3-pole (3PDT). It features a standard ON/OFF flag indicator, and can be ordered with an optional push-to-test operator, a LED and bifurcated or gold bifurcated contacts. Coils are available in a wide range of AC and DC voltages. Contacts are rated up to 10A.
700-HA has eleven features. (1)10A contact rating. (2)DPDT, 3PDT. (3)Pin style terminals. (4)Standard ON/OFF flag indicator. (5)Clear cover for easy visual inspection. (6)Optional push to test and manual override. (7)Optional LED. (8)Optional socket mounted surge suppressor module. (9)Optional multi-function timing module. (10)Type HAB bifurcrated contacts. (11)Type HAX gold bifurcated contacts. That are all the main features.
Some electrical characteristics of 700-HA have been concluded into several points as follow. (1)Its pilot duty rating would be NEMA B300. (2)Its rated thermal current would be 10A at 120V, 240V. (3)Its rated insulation voltage would be 250V IEC - 300V UL/CSA. (4)Its contacts with inductive DC would be 30V DC, 10A. (5)Its min low energy permissible load would be 10V, 50mA. (6)Its permissible coil voltage variation would be 85% to 110% for nominal voltage at 50Hz and would be 85% to 110% of nominal voltage at 60Hz and would be 80% to 110% of nominal voltage at DC. (7)Its coil consumption +/-10% would be 3.3VA inrush and 2.2VA sealed for 50Hz and would be 2.85VA inrush and 1.9VA sealed for 60Hz and would be 1.3W for DC coils. (8)Its max allowable leakage would be 25% of VA and 10% of W.
Also some design specifications of 700-HA are concluded as follow. (1)Its dielectric withstand voltage would be 2000V. (2)Its electrical life operating would be 100000 minutes. (3)Its degree of protection (open type) IEC 529 would be IP 40. (4)Its switching frequency operations would be 3600/HR. And so on. If you have any question or suggestion or want to know more information please contact us for details. Thank you!