6B13HV

MODULE ISOL RTD-IN FIELD CONFIG

product image

6B13HV Picture
SeekIC No. : 004238644 Detail

6B13HV: MODULE ISOL RTD-IN FIELD CONFIG

floor Price/Ceiling Price

Part Number:
6B13HV
Mfg:
Analog Devices Inc.
Supply Ability:
5000

Price Break

  • Qty
  • 1~5000
  • Unit Price
  • Negotiable
  • Processing time
  • 15 Days
Total Cost: $ 0.00

SeekIC Buyer Protection PLUS - newly updated for 2013!

  • Escrow Protection.
  • Guaranteed refunds.
  • Secure payments.
  • Learn more >>

Month Sales

268 Transactions

Rating

evaluate  (4.8 stars)

Upload time: 2024/11/24

Payment Methods

All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Notice: When you place an order, your payment is made to SeekIC and not to your seller. SeekIC only pays the seller after confirming you have received your order. We will also never share your payment details with your seller.
Product Details

Description



Features:

·Single-channel isolated signal-conditioning modules.
·Accepts outputs from platinum, nickel and copper RTD sensors.
·Complete microcomputer-based data acquisition systems.
·Can be remotely reconfigured for various sensor types and input ranges.



Application

·Process Monitoring & Control
·Test Stand Automation
·Machine Monitoring
·Material Testing
·Remote Energy Mangement
·Laboratory Data Acquisition



Description

The 6B13 and 6B13HV are single-channel isolated signalconditioning modules which accept outputs from platinum, nickel and copper RTD sensors. Unlike conventional signal conditioners, the 6B13 and 6B13HV are complete microcomputer-based data acquisition systems. A major advantage of the on-board microcontroller is its ability to be remotely reconfigured for various sensor types and input ranges.

Software Configuration The 6B13 and 6B13HV linearize 100 platinum RTDs (alphas of 0.00385 and 0.003916), 120 nickel RTDs and 10 copper RTDs. Software is used to configure the 6B13 and 6B13HV modules for address, input range, baud rate, data format, checksum status and integration time. All programmable parameters are stored in the nonvolatile memory of the module.

RTD sensor excitation current of 250 uA (2.25 mA for copper RTDs) is supplied by a tracking pair of current sources. The resulting analog input signal is conditioned and scaled by a programmable-gain amplifier and digitized by a 16-bit
integrating converter under microprocessor control. The digitized value is passed serially across a magnetically isolated barrier (1500 V rms Model 6B12; 2500 V rms Model 6B13HV) and clocked in by a custom controller chip. The onboard microprocessor then converts the data into engineering units or as a percentage of full scale, as determined by the channel parameters. In between conversions, the microprocessor auto zeros the offset and gain by monitoring the on-board temperature and compensating for reference drift.The 6B13 and 6B13HV use compensation factors to ensure the highest accuracy possible.




Parameters:

Technical/Catalog Information6B13HV
VendorAnalog Devices Inc.
CategorySensors, Sensor Evaluation Kits
RoHS StatusRoHS Non-Compliant
Other Names 6B13HV
6B13HV



Customers Who Bought This Item Also Bought

Margin,quality,low-cost products with low minimum orders. Secure your online payments with SeekIC Buyer Protection.
Fans, Thermal Management
Crystals and Oscillators
Optical Inspection Equipment
Sensors, Transducers
Semiconductor Modules
Test Equipment
View more