Features: • 3-State Outputs Drive Bus Lines or Buffer Memory Address Registers• Flow-Through Architecture Optimizes PCB Layout• Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise• EPIC™ (Enhanced-Performance Implanted CMOS) 1-m Process• 50...
54AC11241: Features: • 3-State Outputs Drive Bus Lines or Buffer Memory Address Registers• Flow-Through Architecture Optimizes PCB Layout• Center-Pin VCC and GND Configurations Minimize High-...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Storage temperature range . . . . . . . . . . . . . . . . . . .. . . . . . . .. 65°C to 150°C
‡ Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
This octal buffer or line driver 54AC11241 is designed specifically to improve both the performance and density of three-state memory address drivers, clock drivers, and bus-oriented receivers and transmitters. Taken together with the AC11240 and AC11244, these devices provide the choice of selected combinations of inverting and noninverting outputs, symmetrical G (activelow output control) inputs, and complementary G and G inputs. This 54AC11241 features a high fan-out.
The 54AC11241 is characterized for operation over the full military temperature range of 55°C to 125°C. The 74AC11241 is characterized for operation from 40°C to 85°C.