Features: SpecificationsDescription The Agilent 4294A is precision impedance analyzer.Specifications describe the instrument's warranted performance over the temperature range of 0 °C to 40 °C (except as noted). Supplemental performance characteristics of 4294A are intended to provide information ...
4294A: Features: SpecificationsDescription The Agilent 4294A is precision impedance analyzer.Specifications describe the instrument's warranted performance over the temperature range of 0 °C to 40 °C (exce...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The Agilent 4294A is precision impedance analyzer.Specifications describe the instrument's warranted performance over the temperature range of 0 °C to 40 °C (except as noted). Supplemental performance characteristics of 4294A are intended to provide information that is useful in applying the instrument by given non-warranted performance parameters. These are denoted as SPC (supplemental performance characteristics), typical, or nominal.Warm-up time must be greater than or equal to 30 minutes after power on for all specifications.
The Agilent 4294A has some basic characteristics.Impedance parameters is |Z|-, R-X, Ls-Rs, Ls-Q, Cs-Rs, Cs-Q, Cs-D, |Y|-, G-B, Lp-G,Lp-Q, Cp-G, Cp-Q, Cp-D, Complex Z-Y, |Z|-Ls, |Z|-Cs, |Z|-Lp,|Z|-Cp, |Z|-Rs, |Z|-Q, |Z|-D, Lp-Rp, Cp-Rp.Configuration is four-terminal pair configuration.Connector type is four BNC (female) connectors. Can be converted to one port terminal using the Agilent 42942A Terminal Adapter (7-mm port) or 42941A Impedance Probe (3.5-mm port).When accuracy without Option 4294A-1D5.It's ±20 ppm (at 23 ±5 °C) ±40 ppm (at 0 to 55 °C).When accuracy with Option 4294A-1D5.It's ±0.13 ppm (at 0 to 55 °C).
The Agilent 4294A has some paramater about voltage signal level.Range is 5 mVrms to 1 Vrms.Resolution is 1 mV.When accuracy at four-terminal pair port of the 4294A or 7-mm port of the 42942A.It's ±[(10 + 0.05 X f)% + 1 mV] (at 23 ±5 °C).When accuracy at measurement port of the 42941A, 16048G/H.It's ±[(15 + 0.1 X f)% + 1 mV] (at 23 ±5 °C).In the end there has a note:These characteristics apply when OPEN is connected to each port.Test signal level should be 0.5 Vrms when the measured impedance is 50 .Beyond 23 ±5 °C of temperature, test signal level setting accuracy is twice as bad as described.
At present there is not too much information about this model.If you are willing to find more about the Agilent 4294A, please pay attention to our web! We will promptly update the relevant information.