Application·output rectification and freewheeling in inverters, choppers and converters·And input rectifications where severe restrictions on conducted EMI should be met.Specifications MAXIMUM RATINGS 40EPF.. Units Conditions IF(AV) Max. Average Forward Current 40 A @TC = 105° C, 180...
40EPFHV: Application·output rectification and freewheeling in inverters, choppers and converters·And input rectifications where severe restrictions on conducted EMI should be met.Specifications MAXIMUM ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
MAXIMUM RATINGS | 40EPF.. | Units | Conditions | |
IF(AV) Max. Average Forward Current | 40 | A | @ TC = 105° C, 180° conduction half sine wave | |
IFSM Max. Peak One Cycle Non-Repetitive Surge Current |
400 | A | 10ms Sine pulse, rated VRRMapplied | |
475 | 10ms Sine pulse, no voltage reapplied | |||
I2t Max. I2t for fusing | 800 | A2s | 10ms Sine pulse, rated VRRMapplied | |
1131 | 10ms Sine pulse, no voltage reapplied | |||
I2t Max. I2t for fusing | 40 | A | Current decaying linearly to zero in 1 sec Frequency limited by TJ max. VA = 1.5 x VR typical |