DescriptionThe 2PA1774R is one member of the 2PA1774 series.These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use...
2PA1774R: DescriptionThe 2PA1774R is one member of the 2PA1774 series.These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The 2PA1774R is one member of the 2PA1774 series.These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.
Features of the 2PA1774R are:(1)low current (max. 100 mA); (2)low voltage (max. 40 V).Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
The absolute maximum ratings of the 2PA1774R can be summarized as:(1)collector to base voltage:-60 V;(2)collector to emitter voltage:-40 V;(3)storage temperature:-65 to 150;(4)emitter base voltage:-5V;(5)collector current:-100mA;(6)junction temperature:150;(7)total power dissipation:150mW. 2PA1774R described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite).