Rectifiers 2A 50V
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Product : | Standard Recovery Rectifiers | Configuration : | Single | ||
Reverse Voltage : | 50 V | Forward Voltage Drop : | 1 V | ||
Forward Continuous Current : | 2 A | Max Surge Current : | 60 A | ||
Reverse Current IR : | 5 uA | Mounting Style : | Through Hole | ||
Package / Case : | DO-15 | Packaging : | Reel |
Part Number | 2A01 |
Total Capacitance CT (pF) |
15 |
Max Average Rectified Current IO (A) |
2 |
Peak Repetitive Reverse Voltage VRRM (V) |
50 |
Peak Forward Surge Current IFSM (A) |
70 |
Forward Voltage Drop VF (V) |
1.1 |
Max Reverse Current IR (µA) |
5 |
Characteristic |
Symbol |
2A01 |
2A02 |
2A03 |
2A04 |
2A05 |
2A06 |
2A07 |
Unit |
---|---|---|---|---|---|---|---|---|---|
Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage |
VRRM VRWM VR |
50 |
100 |
200 |
400 |
600 |
800 |
1000 |
V |
RMS Reverse Voltage |
VR(RMS) |
35 |
70 |
140 |
280 |
420 |
560 |
700 |
V |
Average Rectified Output Current (Note 1) @ TA = 55°C |
IO |
2.0 |
A | ||||||
Non-Repetitive Peak Forward Surge Current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) |
IFSM |
70 |
A | ||||||
Forward Voltage @ IF = 2.0A |
VFM |
1.1 |
V | ||||||
Peak Reverse Leakage Current @TA = 25°C at Rated DC Blocking Voltage@ TA = 100°C |
IRM |
5.0 50 |
µA | ||||||
I2t Rating for Fusing (t < 8.3ms) |
I2t |
17.5 |
A2s | ||||||
Typical Junction Capacitance (Note 2) |
Cj |
15 |
pF | ||||||
Typical Thermal Resistance Junction to Ambient (Note 1) |
RJA |
60 |
K/W | ||||||
Operating and Storage Temperature Range |
Tj, TSTG |
-65 to +150 |
°C |