Features: • Operates as pulse transformer• Operates as analog transformer• Can be configured as 1 : 1 or 1 : 2CT isolation transformer• Can be configured as 1 : 3 auto transformer• Operating temperature range: -40to +85• Meets IEC 695, 2-2 flammability requireme...
2664G: Features: • Operates as pulse transformer• Operates as analog transformer• Can be configured as 1 : 1 or 1 : 2CT isolation transformer• Can be configured as 1 : 3 auto transf...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Part Number |
Turns Ratio ± 3% |
Inductance1 H min |
DCR max |
Leakage Inductance2 H max |
Interwinding
Capacitance pF typ |
Minimum
Interwinding Breakdown Voltage Vrms | ||
(4-6):(3-8):(7-1) |
(4-6) |
(3-8) |
(3-8) |
(3-8) |
(4-6) | |||
2664G |
1 : 1 : 1 |
120 |
0.3 |
0.3 |
0.3 |
0.31 |
30 |
100 |