Schottky (Diodes & Rectifiers) 30 Amp 35 Volt Common Cathode
25CTQ035: Schottky (Diodes & Rectifiers) 30 Amp 35 Volt Common Cathode
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: 150 TJ operation Center tap TO-220 package High purity, high temperature epoxy encapsul...
Product : | Schottky Rectifiers | Peak Reverse Voltage : | 35 V |
Forward Continuous Current : | 30 A | Max Surge Current : | 990 A |
Configuration : | Dual Common Cathode | Forward Voltage Drop : | 0.71 V |
Maximum Reverse Leakage Current : | 1750 uA | Operating Temperature Range : | - 55 C to + 150 C |
Mounting Style : | Through Hole | Package / Case : | TO-220AB |
Packaging : | Tube |
The 25CTQ035 center tap Schottky rectifier series has been optimized for very low forward voltage drop, with moderate leakage. The proprietary barrier technology allows for reliable operation up to 150 junction temperature. Typical applications of 25CTQ035 are in switching power supplies, converters, free-wheeling diodes, and reverse battery protection.
The 25CTQ035 has six features.The first one is 150 TJ operation.The second one is center tap TO-220 package.The third one is high purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance.The fourth one is very low forward voltage drop.The fifth one is high frequency operation.The sixth one is guard ring for enhanced ruggedness and long term reliability.
The 25CTQ035 has some absolute maximum ratings.When parameter is IF(AV) Max. average forward (Per Leg) current(Per Device),the limits is 30,the units is A,the condition is 50% duty cycle @ TC = 102, square wave form.When parameter is IFSM Max. peak one cycle non-repetitive surge current (Per Leg),the limits is 990,the units is A,the condition is 5s sine or 3s rect.pulse following any rated load condition and with rated VRRM applied.When parameter is IFSM Max. peak one cycle non-repetitive surge current (Per Leg),the limits is 250,the units is A,the condition is 10ms Sine or 6ms rect.pulse following any rated load condition and with rated VRRM applied.When parameter is EAS non-repetitive avalanche energy,the limits is 20,the units is mJ,the condition is TJ = 25, IAS=3 Amps,L=4.40 mH.When parameter is IAR repetitive avalanche current,the limits is 3,the units is A,the condition is current decaying linearly to zero in 1 sec frequency limited by TJ max. VA = 1.5 x VR typical.