Features: * Metal case for Maximum Heat Dissipation* Surge overload ratings-400 Amperes* Low forward voltage dropSpecificationsRatings at 25 oC ambient temperature unless otherwise specified.Single phase, half wave, 60 Hz, resistive or inductive load.For capacitive load, derate current by 20%. ...
2508W: Features: * Metal case for Maximum Heat Dissipation* Surge overload ratings-400 Amperes* Low forward voltage dropSpecificationsRatings at 25 oC ambient temperature unless otherwise specified.Single ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
KBPC | KBPC | KBPC | KBPC | KBPC | KBPC | KBPC | ||||
25005W | 2501W | 2502W | 2504W | 2506W | 2508W | 2510W | ||||
SYMBOL | MB2505W | MB251W | MB252W | MB254W | MB256W | MB258W | MB2510W | UNITS | ||
Maximum Recurrent Peak Reverse Voltage | VRRM | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | Volts | |
Maximum RMS Bridge Input Voltage | VRMS | 35 | 70 | 140 | 280 | 420 | 560 | 700 | Volts | |
Maximum DC Blocking Voltage | VDC | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | Volts | |
Maximum Average Forward Rectified Output Current at Tc = 55 | IO | 25 | Amps | |||||||
Peak Forward Surge Current 8.3 ms single half sine-wave | IFSM | 400 | Amps | |||||||
superimposed on rated load (JEDEC Method) | ||||||||||
Maximum Forward Voltage Drop per element at 12.5A DC | VF | 1.1 | Volts | |||||||
Maximum DC Reverse Current at Rated | @TA = 25 | IR | 10 | uAmps | ||||||
DC Blocking Voltage per element | @T = 100 | 500 | ||||||||
I2t Rating for Fusing (t<8.3ms) | I2t | 374 | A2Sec | |||||||
Typical Junction Capacitance ( Note1) | CJ | 300 | pF | |||||||
Typical Thermal Resistance (Note 2) | RqJC | 2.5 | /W | |||||||
Operating and Storage Temperature Range | TJ,TSTG | -55 to + 150 |