Published:2009/7/20 21:25:00 Author:Jessie | From:SeekIC
Dual-voltage transmitter power supply with 800-volt and 450-volt taps.This circuit Will handle a 100-watt transmitter,The 800-volt tap is rated at 175 mA intermittent duty with 1% ripple and 16% load rejection.The 450-volt tap is rated at 25 mA with 0.02% ripple. The voltage at V2 can be lowered to 375 volts by removing C3,The current rating of V2 can be Increased by selecting L3 with a higher current rating(courtesy General Electric Company).
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Power_Supply_Circuit/Dual_voltage_transmitter_power_supply_with_800_volt_and_450_volt_taps.html
Print this Page | Comments | Reading(3)