Published:2012/11/29 0:50:00 Author:Ecco | Keyword: High-accuracy , pressure measurement system , intelligent , dual-channel sensor, signal processor | From:SeekIC
Bridge pressure sensor's output voltage is connected to the MAX1463 IN1+ IN1-side. Under CPU control, pressure signal is converted by nonlinear calibration, temperature compensation and ADC conversion, then it is sent to 80C51 MCU after being output from the serial interface; DAC also can convert it to the analog output voltage Uo, then it is sent to a digital voltmeter to show the measured pressure value. GPI01 universal digital I/O interface pin is connected to failure alarm, and the leader of sensor is open or CPU occurs overflowing, it can drive the buzzer alarm to emit sounds.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Measuring_and_Test_Circuit/High_accuracy_pressure_measurement_system_circuit_diagram_composed_of_intelligent_dual_channel_sensor_signal_processor_MAX1463.html
Print this Page | Comments | Reading(3)
Code: