Published:2011/6/20 8:57:00 Author:Fiona | Keyword: consisting of 555, the indoor humidity control | From:SeekIC
The controller is composed of step-down rectifier circuit,humidity sensor,single stable circuit,Silicon controlled control circuit and so on.Step-down rectifier circuit provides DC voltage VDD=+10V for the whole control circuit.Single stable circuit is composed of IC,wet sensitive network,R5,C1 and so on. When the humidity exceeds the predetermined value,555 ② pin potential is high,555 is reset,the low level output by ③ pin makes the SCR conduct,turns on exhaust fan power To do exhaust to reduce humidity.Emission time is determined by timing time constant R5C1 and the level of control terminals ⑤ pin.Adjust W1 be preset the emission time.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Control_Circuit/consisting_of_555_the_indoor_humidity_control_circuit.html
Print this Page | Comments | Reading(3)
Code: