Published:2009/6/24 5:33:00 Author:May | From:SeekIC
The charging current of a capacitor can be used if a momentary relay-on circuit is needed Depending fin the relay characteristics,C will vary from 1000 to 4000 μF or so for a 1-s hold time if a 500-Ω relay is used.RD discharges capacitor C to reads,the circuit for the next oPeration The valueshould be high enoughso as notto maintian the relay closure at highest expected supply voltage.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Control_Circuit/Relay_Control/MOMENTARY_RELAY_CIRCUIT.html
Print this Page | Comments | Reading(3)
Code: