Published:2009/7/13 23:13:00 Author:May | From:SeekIC
Uses triac to provide current for inductive load during both positive and negative alternations of AC source, with optoisolator providing complete isolation for logic control circuit. MDA920-4 diode bridge provides pulsating DC voltage for photo-SCR of optoisolator so gate current is supplied to triac for both halves of AC cycle.-T. Mazur, Solid-State Relays Offer New Solutions to Many Old Problems, EDN Magazine, Nov. 20,1973, p 26-32.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Control_Circuit/FULL_WAVE_CONTROL.html
Print this Page | Comments | Reading(3)
Code: