Published:2009/7/7 3:22:00 Author:May | From:SeekIC
This circuit allows zero adjustment as well as slope adjustment. The ICL8069 brings the input within the common-mode range, while the 5 k ohm pots trim any offset at 218°K (-55℃), and set the scale factor.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/Basic_Circuit/BASIC_DIGITAL_THERMOMETER,KELVIN_SCALE_WITH_ZERO_ADJUST.html