Published:2011/6/7 4:13:00 Author:Borg | Keyword: protection circuit | From:SeekIC
See as Figure 13-8, the protector is formed by sub-circuits of the step-down rectifier, delay starter, over/low voltage sample and trigger,etc. The protector has functions of over voltage (>245v) and low voltage(<175v) protection, off-delay operation(about 7 minutes) and so on, and it's power saving(<2w) and cost saving.
Figure 13-8. Theexternalprotection circuit of fridges
IC(555), R4 and C3 consist the single steady delay circuit, the delaying time is td=1.1R4C3, the delaying time of the parameter in the figure is about 7min. When the circuit is protecting the fridge, LED1(red) is glowing, and the fridge outlet is cut off; when it is working normally, LED2(green) is glowing.
Reprinted Url Of This Article:
http://www.seekic.com/circuit_diagram/555_Circuit/The_protection_circuit_of_555_fridge.html
Print this Page | Comments | Reading(3)